Oct 25, 2012  this is a tutorial on how to bypass a zone on a DSC security system. How to bypass a zone on DSC security system supersecurity101dsc. DSC Power Series User Code Programming. PC1616/PC1832/PC1864 version 4.1 Installation Guide Note to Installer:Center pages contain important end user information. Leave with End User. WARNING: This manual contains information on limitatio ns regarding product use an d function and infor-mation on the limitations as to liability the manufacturer. The entire manual should be carefully. PC1616/PC1832/PC1864 v4.6 NA Installation Guide WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability the manufacturer. The entire manual should be read carefully.

Advertising

How to Program:

DSC recommends filling in the Programming Worksheet with the required
programming information before programming the system. This will reduce the
time required to program and will help eliminate errors.

To enter Installer Programming press [*][8][5555].
The Program light will FLASH (or in the case of the programmable LCD keypad
the display will change to ‘Enter Section’).

An error tone indicates the installer code entered is not correct.
Press [#] to clear any key presses and try again

.

The Armed and Ready lights indicate programming status:

Armed Light ON

Panel waiting for 3-digit section number

Ready Light ON

Panel waiting for data to be entered

Ready Light FLASHING

Panel waiting for HEX data to be entered

NOTE:

You cannot enter installer programming while the system is armed or
in alarm.

Programming Toggle Options:

Enter the 3-digit programming section number.

The Armed light will turn OFF and

The Ready light will turn ON.

The keypad will display which toggle options are ON or OFF according to
the chart below:

To toggle an option ON or OFF, press the corresponding number on the
keypad. The display will change accordingly.

When all the toggle options are configured correctly, press the [#] key to
exit the program section.

The Ready light will turn OFF and the Armed light will turn ON.

NOTE:

If the panel is a local system, press [#] to skip this step.

NOTE:

In addition to the standard digits 0-9, HEX digits can also be
programmed if required.

Programming Decimal and Hexadecimal (HEX) Data:

Enter the 3-digit programming section number.

The Armed light will turn OFF and The Ready light will turn ON.

Enter the data written in the boxes.

For sections that require multiple 2 or 3 digit numbers, the keypad will
double-beep after each 2 or 3 digit entry and move to the next item in
the list. After the last digit in the section is entered, the keypad will
beep rapidly 5 times and exit the program section. The Ready light will
turn OFF and the Armed light will turn ON.

For sections that do not require data for every box (such as phone
numbers) press the [#] key to exit the program section after entering all

the required data. The Ready light will turn OFF and the Armed light
will turn ON.
At any time the [#] can be pressed to exit any program section. All
changes made up to that point will be saved.

HEX (or hexadecimal) digits are sometimes required. To enter a HEX
digit, press the [*] key to begin HEX programming. The Ready light will
FLASH. Refer to the chart below and press the number corresponding
to the HEX digit required. The Ready light will continue to FLASH.
Press [*] again to return to normal decimal programming. The Ready
light will turn ON.

HEX [A]

[*] [1] [*]

HEX [B]

[*] [2] [*]

HEX [C]

[*] [3] [*]

HEX [D]

[*] [4] [*]

HEX [E]

[*] [5] [*]

HEX [F]

[*] [6] [*]

How to Exit Installer Programming:

To exit installer programming, press the [#] key when the panel is
waiting for a 3-digit section number (the Armed light is ON).

Viewing Programming

LED and LCD5501Z Keypads

Any programming section can be viewed from an LED or LCD5501Z key-
pad. When a programming section is entered, the keypad will immediately
display the first digit of information programmed in that section.
The keypad displays the information using a binary format, according to
the following chart:

See Hex data

entry instructions

Dsc 1616 Programming Manual Pdf

Press any of the Emergency keys (Fire, Auxiliary or Panic) to advance to
the next digit.
When all the digits in a section have been viewed, the panel will exit the
section: the Ready light will turn OFF, and the Armed light will turn ON,
waiting for the next 3-digit programming section number to be entered.
Press the [#] key to exit the section

LCD Keypad

When a programming section is entered, the keypad will immediately dis-
play all the information programmed in that section. Use the arrow keys (<
>) to scroll through the data being displayed. To exit the section, scroll
past the end of the data displayed, or press the [#] key.

DLS Programming

Hardware Setup - Local (PC-Link)

Connect a RS-232 to PC-Link Cable between the Computer with DLS
Software installed and the alarm panel to be programmed.

[401] First Downloading Option Code

The 1

st

toggle option in this section is used to enabled/disable Downloading.

Configure the options as required and press [#] to exit

.

PROGRAMMING

Keypad Type

Option ON

Option OFF

LED

Zone Light ON

Zone Light OFF

Fixed-Message LCD

Indicator # ON

Indicator # OFF

Programmable-Message LCD

# Displayed

Dash [-] Displayed

HEX [A]
HEX [B]
HEX [C]
HEX [D]
HEX [E]

Not Supported
Simulated [*] key
Simulated [#] key
Dial tone search
Two second pause

Press [*][2][*]
Press [*][3][*]
Press [*][4][*]
Press [*][5][*]

Opt

Default

Description

2

I__I

Dsc 1616 installation manual

ON

User can enable DLS Window

OFF

User can NOT enable DLS Window

Advertising
This manual is related to the following products:
Popular Brands
Popular manuals
Advertising

Trouble

Cause

Troubleshooting

Trouble [5] Zone Fault (Cont.)

One or more wireless devices have
not checked in within the
programmed time

If the trouble occurs immediately, a conflict with a hard
wired zone exists:
• The zone being used is already assigned to a

PC5108 zone expander

• The zone being used is assigned as a keypad zone

Perform a Module Placement Test – Program Section
[904] and verify the wireless device is in a good location.
• If bad test results occur, test the wireless device in

another location

• If the wireless device now tests good, the original

mounting location is bad

• If the wireless device continues to give bad test

results replace the wireless device

A short circuit is present on one or
more zones with double end-of-line
resistors enabled

Remove the wire leads from Z and COM terminals and
measure the resistance of the wire leads.
• A short circuit indicates a short in the wiring.

Connect a 5.6K resistor (Green, Blue, Red) across the Z
and COM terminals.
• Verify the trouble condition clears.

Trouble [6] Zone Tamper

Press [6] to determine specific zones with a tamper trouble

A tamper condition is present on one
or more wireless devices

Perform a Module Placement Test –Section [904]

Violate, then restore the tamper:
• If no test result then replace wireless device

An open circuit is present on one or
more zones with double end-of-line
resistors enabled

Remove the wire leads from Z and COM terminals.

Measure the resistance of the wire leads.
• Open circuit indicates a break in the wiring.

Connect a 5.6K resistor (Green, Blue, Red) across the Z
and COM terminals.
• Verify the trouble condition clears.

Trouble [7] Wireless Device Low Battery Press [7] to toggle through specific devices with low battery trouble

1st press – Wireless Zones

2nd press – Handheld Keypads

3rd press – Wireless Keys

One or more wireless devices has a
low battery

NOTE: The event will not be logged
to the event buffer until the wireless
device low battery delay time expires

• Program Section [377] Opt 9

Replace battery

NOTE: Replacing batteries will cause a tamper. Replacing
cover will restore the tamper causing the associated report-
ing codes to be sent to the Central Station.

Trouble [8] Loss of Clock/Date

The main panel internal clock is not
set

To program the time and date:

Enter [

✱][6][Master Code] then Press [1]

Dsc 1616 User Manual Pdf

or Press function key programmed with definition #26

Enter the time and date (in military) using the following
format: HH:MM MM/DD/YY

Example.

For 6:00 pm, June 29, 2005

Enter: [18] [00] [06] [29] [05]

IMPORTANT!

Ensure you have the following information available before contacting Customer Support

- Control Panel Type and Version, (e.g., PC1864 v4.1)

NOTE: Version number can be accessed by entering [

][Installer Code][900] on any system keypad. This information is

also located on a sticker on the Printed Circuit Board.

- List of modules connected to Control Panel, (e.g., PC5400, PC5204 etc.)