1. Movincool Office Pro 60 Service Manual
  2. Movincool Office Pro 36
  3. Movincool Office Pro 12
  4. Movincool Office Pro 36 Manual
  5. Movincool
  6. Movincool Office Pro 60 Manual
  • Portable Specialty Coolers Office Pro 60. Providing up to 60,000 Btu/hr of cooling capacity, more than twice the cooling power of the Office Pro 24, the Office Pro 60 portable air conditioner is specifically designed for large office spaces and computer rooms filled with heat-generating electronics.
  • Computer Cooling Office & Server Room Air Conditioner Units. Providing up to 60,000 Btu/hr of computer cooling capacity (more than twice the cooling power of the Office Pro 24), the Office Pro 60 portable air conditioner is specifically designed for cooling large office spaces and computer rooms that house heat-generating electronics.
Movincool office pro 60 user manual 2017

Www.movincool.com operation manual office pro 60 read this manual carefully for instructions on correct installation and usage, and read all safeguards. Postage will be paid by adressee first-class mail permit no. 8390 long beach, ca business reply mail denso sales california, inc. 3900 via oro avenue long beach, ca no postage.

Advertising

Jul 28, 2009  When server rooms are set up in existing office space, as most are, they are usually provided the same amount of cooling as the 'people space.' The problem is that servers produce much more heat than people in an office. Enter the Movincool Office Pro 60 Portable Air Conditioner. Www.movincool.com operation manual office pro 60 read this manual carefully for instructions on correct installation and usage, and read all safeguards. Postage will be paid by adressee first-class mail permit no. 8390 long beach, ca business reply mail denso sales california, inc. 3900 via oro avenue long beach, ca no postage.

Repair Section

36

Indication of service

code

Press ON/OFF and

U buttons

simultaneously for 3 sec. Indication

contents is as follows.

1) See page 36 and 37.

2) Press ON /OFF button.

Change model setting

Movincool Office Pro 60 User Manual

For installing new controller PCB, if

a different model name appears

when the unit is reset or turned on,

change model name according to

the correct procedure.

1) While pressing

U and V

buttons, plug the power cord.

<Condition>

LCD indicates current setting

model name and buzzer sounds.

2) After setting the model type by

pressing

U and V button, 

unplug the unit.

Activation of high

pressure switch

When high pressure switch

(connected to J104) activates

(=J104 input turns to open) 3 times

in 24 h, “HP” is indicated and signal

output (J106) turns on.

Movincool Office Pro 60 Service Manual

When it activates 10 times in 24 h,

“FAIL HP” is indicated and buzzer

sounds.

Find the cause of high pressure to

address it.

Check the following.

Ambient air temperature

(65 °F (18.3 °C),

50

%

RH

95 °F (35 °C), 60 %RH)

Movincool Office Pro 60 User Manual

Air filter (if dirty, wash up.)

Condenser fan motor (if not

working, replace.) Defect of high

pressure switch (if switch is open

when unit is off, replace switch.)

Reset the system.

To RESET: Press ON/OFF and

HI/LO buttons on the control box

simultaneously for 5 sec.

LCD Display

Description

Condition

Reset/Remedy

LCD

DF

FZ

Movincool Office Pro 36

OD

Description

Value

Defrost status

Evap. out pipe
temperature

26

109F

(“26”

“X9”)

Outdoor
temperature

0 (“00”)

TU

AM

F

SET TEMP

Movincool Office Pro 12

HI

Movincool Office Pro 36 Manual

ON

COOL

Movincool

FAN

Advertising
This manual is related to the following products:

Classic Plus 26 Service Manual, Classic Plus 14 Service Manual, Office Pro 12 Service Manual, Office Pro 18 Service Manual, Office Pro 24 Service Manual, Office Pro W20 Service Manual, Office Pro 36 Service Manual, Office Pro 60 Service Manual

Movincool Office Pro 60 Manual

Popular Brands
Popular manuals